onlinecomponents.com
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
35
Branch
Circuit
Fuses
Low Voltage, Branch Circuit Rated Fuses
60
100
200
400
600
30
15
10
8
Time-Current Characteristic Curves—Average Melt
Fusetron
®
Dual-element, Time-delay Fuses
Specifications
Description: Dual-element, time-delay
fuse – 10 seconds (minimum) at 500%
rated amps (8 seconds for 0-30A sizes).
Available with indication on select ratings
(see Catalog Numbers table).
Dimensions: See page 15 for Class RK5
dimensions.
Ratings:
Volts — 250Vac (or less)
— 125Vdc (
1
10-60A, 110-200A)
— 250Vdc (225-600A)
Amps
1
10-600A
IR — 200kA RMS Sym.
— 20kA DC
Agency Information: CE, Std. 248-12, Class RK5,
UL Listed, Guide JDDZ, File E4273, CSA Certified, Class
1422-01, File 53787.
Features and Benefits
• Separate overload and short-circuit elements provide time
delay for sizing as close as 125% of motor FLA.
• 2:1 selective coordination amp ratio (within the Cooper
Bussmann RK5 fuse family) prevents overcurrent events
from opening upstream Fusetron fuses.
• Insulated end caps for 225A-600A fuses reduces exposure
to live parts and extends air gap to distance between
blades of adjacent mounted fuses or to housing.
Typical Applications
• Power Panelboards
• Motor Control Centers
Catalog Numbers (Amps)
FRN-R-
1
10 FRN-R-2 FRN-R-10* FRN-R-100
FRN-R-
1
8 FRN-R-2-
1
4 FRN-R-12* FRN-R-110
FRN-R-
15
100 FRN-R-2-
1
2 FRN-R-15* FRN-R-125
FRN-R-
2
10 FRN-R-2-
8
10 FRN-R-17-
1
2* FRN-R-150
FRN-R-
1
4 FRN-R-3 FRN-R-20* FRN-R-175
FRN-R-
3
10 FRN-R-3-
2
10 FRN-R-25* FRN-R-200
FRN-R-
4
10 FRN-R-3-
1
2 FRN-R-30* FRN-R-225
FRN-R-
1
2 FRN-R-4 FRN-R-35* FRN-R-250
FRN-R-
6
10 FRN-R-4-
1
2 FRN-R-40* FRN-R-300
FRN-R-
8
10 FRN-R-5 FRN-R-45* FRN-R-350
FRN-R-1 FRN-R-5-
6
10 FRN-R-50* FRN-R-400
FRN-R-1-
1
8 FRN-R-6 FRN-R-60* FRN-R-450
FRN-R-1-
1
4 FRN-R-6-
1
4 FRN-R-70 FRN-R-500
FRN-R-1-
4
10 FRN-R-7 FRN-R-75 FRN-R-600
FRN-R-1-
1
2 FRN-R-7-
1
2 FRN-R-80
FRN-R-1-
6
10 FRN-R-8* FRN-R-85
FRN-R-1-
8
10 FRN-R-9* FRN-R-90
Data Sheets: 1019 (0-60) and 1020 (70-600)
Data Sheet: 1169 (8-60) FRN-R with indication
Instantaneous Peak Let-Through Current Amps
RMS Symmetrical Currents In Amps
A–B = Asymmetrical Available Peak (2.3 x Sym RMS Amps)
400,000
100,000
10,000
1,000
1,000
10,000
100,000
200,000
60
600
100
Amp
Rating
400
200
B
A
30
FRN-R
Current Limitation Curves
FRN-R (250V) Class RK5
*Available with indication.To order, place “ID” at the end of the catalog number.
• Combination Starters
• Machinery Disconnects
Recommended Fuse Reducers For Class R Fuses
• See page 14
For superior electrical protection,Cooper Bussmann recommends upgrading FRN-R
fuse applications to Low-Peak
®